Class II Division I means the project site may produce combustible dust normally when the project operates, here are some recommended explosion proof lighting, control box and fittings for your options subject to NEC UL and CSA standard.

What is A Class 2 Div 1 Area?

Class 2 Div 1 Definition
Class 2 Div 1 Definition

In Simple Word

Class 2 Div 1 location, C2D1 for short, , Class 2 Division 1 for full name, means ignitable concentrations of hazards, such as flammable dust, exists under normal operation conditions and/or where hazard is caused by frequent maintenance or repair work or frequent equipment failure.


In Quantitative Measurement

Class 2 Div 1 location means ignitable concentrations of hazards, such as flammable dust, present more than 10 hours every year.

Class 2 Division 1 Electrical Requirements
In Accordance with NEC Article 500

A Class 2, Division 1 location is a location:

  • In which combustible dust is in the air under normal operating conditions in quantities sufficient to produce explosive or ignitible mixtures, or


  • Where mechanical failure or abnormal operation of machinery or equipment might cause such explosive or ignitible mixtures to be produced, and might also provide a source of ignition through simultaneous failure of electrical equipment, through operation of protection devices, or from other causes, or


  • In which Group E combustible dusts may be present in quantities sufficient to be hazardous in normal or abnormal operating conditions.

C2D1

UL/Intertek

Nema4X

Explosion Proof Lighting

Explosion Proof Boxes

Explosion Proof Fittings

Explosion Proof High Bay Lighting
Explosion Proof Led High Bay Lights Class 1 Div 2 Zone 2 SHB-II Series

Class I Division 2     

Zone 2, Zone 21&22

LED 30-300W

Type 4X, IP66

View More
Explosion Proof Led High Bay Lights Class 1 Div 2 Zone 2 SVM Series

Class I Division 2

Zone 2, Zone 21&22

LED30-240W

Type 4X, IP66

View More
Explosion Proof Flood Light
Explosion Proof Led Flood Light Class 1 Div 2 Zone 2 SHF-II Series

Class I Division 2

Zone 1&2, Zone 21&22

LED 20-180W

Type 4X, IP66

View More
Explosion Proof Led Flood Light Class 1 Div 2 Zone 2 SHF-IIA Series

Class I Division 2

Zone 2, Zone 21&22

LED 20-400W

Type 4X, IP66

View More
Explosion Proof Led Gas Station Canopy Lights Class 1 Div 2 Zone 2 SCP Series

Class I Division 2 

Zone 2, Zone 21&22 

LED 40-150W 

Type 4X, IP66

View More
Explosion Proof Fluorescent Lighting
Explosion Proof Emergency Lighting
Explosion Proof Led Emergency Bug-eye Lights SEG Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 2x5W

Type 4X, IP66

View More
Explosion Proof Led Emergency Exit Sign Lights SES Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 5W

Type 4X, IP66

View More
Explosion Proof Alarm Lights SAV Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 5W

Type 4X, IP66

View More
Explosion Proof Flashlight
Explosion Proof Led Class 1 Div 1 Flashlight SPL-A Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 2x5W

Type 4X, IP67

View More
Explosion Proof Led Class 1 Div 1 Torch Lights SPL-B Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 5W

Type 4X, IP65

View More
Explosion Proof Led Division 2 Flashlight SPL-C Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 5W

Type 4X, IP68

View More
Explosion Proof Led Flashlight Portable Search Lights SPL-D Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 2x5W

Type 4X, IP65

View More
Explosion Proof Led Flashlight Portable Work Lights SPL-E Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 5W

Type 4X, IP65

View More
Explosion Proof Led Flashlight Portable Headlamp SPL-F Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 5W

Type 4X, IP67

View More
Explosion Proof Switch
Explosion Proof Lighting Switch SW-P Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.32A

Type 4X, IP66

Built-in Switch

View More
Explosion Proof Junction Box
Explosion Proof Junction Box Class 1 Div 2 Ex e Junction Box SJB-A-e Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.125A

Type 4X, IP66

Built-in Terminal blocks

View More
Explosion Proof Junction Box Glass Reinforced Plastic Ex e SJB-P Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.125A

Type 4X, IP66

Built-in Terminal blocks

View More
Explosion Proof Junction Box Stainless Steel Junction Box Ex e SJB-S Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.125A

Type 4X, IP66

Built-in Terminal blocks

View More
Explosion Proof Panel
Explosion Proof Panel Ex de 11b Hazardous Area Control Systems SPN-de-IIB Series

C1D1, C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.630A

Type 4X, IP66

Built-in Terminal blocks

View More
Explosion Proof Panel Glass Reinforced Plastic Atex DB SPN-ed-P Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.160A

Type 4X, IP66

Built-in Terminal blocks

View More
Explosion Proof Panel Class 1 Div 2 Miniature Circuit Breaker SPN-ed-S Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.160A

Type 4X, IP66

Built-in Terminal blocks

View More
Explosion Proof Enclosure
Explosion Proof Receptacle
Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

<125A

Type 4X, IP66

View More
Explosion Proof Cable Gland
Explosion Proof Cable Gland Exe Cable Gland SGP Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.M63x1.5

Type 4X, IP65

Plastic

View More
Explosion Proof Cable Gland Flameproof Cable Gland SGM Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.M75x1.5(NPT 2 1/2")

Type 4X, IP66

Mental

View More
Explosion Proof Cable Gland Hazardous Area Cable Glands SGN Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.M75x1.5(NPT 2 1/2")

Type 4X, IP66

Non-armored

View More
Explosion Proof Cable Gland Hazardous Area Cable Glands SGA Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.M75x1.5(NPT 2 1/2")

Type 4X, IP66

Armored

View More
Explosion Proof Connector
Explosion Proof Connector Adaptors SA Series

C1D1, C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.115x1.5(NPT 4")

Type 4X, IP66

View More
Explosion Proof Connector Explosion Proof Reducing Bushing SR Series

C1D1, C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.115x1.5(NPT 4")

Type 4X, IP66

View More
Explosion Proof Connector Explosion Proof Unions SU Series

C1D1, C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.115x1.5(NPT 4")

Type 4X, IP66

View More
Explosion Proof Connector Elbows SE Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.115x1.5(NPT 4")

Type 4X, IP66

View More
Explosion Proof Connector Conduit Hubs SH Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.115x1.5(NPT 4")

Type 4X, IP66

View More
Explosion Proof Connector Class 1 Div 2 Liquid Tight Connectors SL Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.115x1.5(NPT 4")

Type 4X, IP66

View More
Explosion Proof Conduit Fittings
Explosion Proof Conduit Body Outlet Fittings Couplings SCB Series

C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.63x1.5(NPT 2")

Type 4X, IP66

View More
Explosion Proof Sealing Fittings Couplings SCS Series

C1D1, C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.63x1.5(NPT 2")

Type 4X, IP66

View More
Explosion Proof Flexible Conduit Couplings SFC Series

C1D1, C1D2, C2D1, C2D2

Zone 1&2, Zone 21&22

Max.63x1.5(NPT 2")

Type 4X, IP66

View More

FAQ for Class 2 Div 1

Q

Does Class 2 Div 1 require explosion proof?

A

Yes, Class 2 Div 1 require explosion proof. The hazardous dusts are easily to be ignored the dangerous grade but they are also can be ignited to form an explosion, particularly the concentration of combustible dust is high in Class 2 Division 1 location, causing the similar explosion potential compared with flammable gases in Class 1 Div 1 location, electrical boxes should be housed in confined space to restrain the explosion transmitting to surrounds, so Class 2 Div 1 should require explosion proof.

Q

What is a Class II Division 1 location?

A

Class II Division 1, so-called Class 2 Division 1, Class II Div 1 location is a place where combustible dusts like metal dusts, carbonaceous dusts, non-conductive dusts exist when normal operation, in order to make sure the safety, all electrical devices including lighting fixtures, control box, receptacle should be explosion proof to resist any mechanical impact and limit the explosive factors.

FAQ for Explosion Proof Lighting Class 2 Div 1
FAQ for Explosion Proof High Bay Lighting Class 2 Div 1
Q

What is a Class 2 enclosure?

A

Class 2 enclosure is explosion proof enclosure for usage in Class 1 hazardous location where flammable dust present under normal or abnormal condition. Any electrical parts should be put inside Class 2 enclosure to isolate the ignition source or prevent the heat from being the ignition source to be worked as explosion proof electrical equipment, it is widely applied for  grain processing, flour and feed mills industry.

Q

What is the difference between Class 2 Div 1 and Div 2 hazardous area?

A

Class 2 hazardous area define the same explosive or ignitable substance-combustible dusts in the environment, the significant difference between Class 2 Div 1 and Class 2 Div 2 is durable time of the combustible dust present, Class 2 Div 1 may present for more than 10 hours, instead, Class 2 Div 2 only present for one to ten hours, thus, Class 2 Div 1 condition is harsher and more dangerous than Class 2 Div 2.

Q

Can equipment approved for a Class I hazardous location be used in a Class II hazardous location?

A

No, Equipment only approved for Class I hazardous location can NOT be used in Class II, besides, equipment only approved for Class II hazardous location can NOT be used in Class I. Class I and Class II are applied with different explosion proof technology. Class I approved equipment are normally designed with flame proof, increased safety explosion proof structure to use in combustible dust hazardous location, instead, Class II approved equipment are commonly designed with housing protection explosion proof structure. 